Military Standard MS24171-D2 Relay, Electromagnetic
Part#: MS24171-D2
by Military Standard
Overall Length: 4.500 Inches Maximum
Center To Center Distance Between Mounting Facilities Parallel To Length: 2.396 Inches Minimum Single Mounting Facility And 2.416 Inches Maximum Single Mounting Facility
Overall Height: 3.313 Inches Maximum
Overall Width: 2.000 Inches Maximum
Case Material: Metal
Environmental Protection: Shock Resistant
Unthreaded Mounting Hole Diameter: 0.256 Inches Minimum Single Mounting Facility And 0.276 Inches Maximum Single Mounting Facility
Fragility Factor: Moderately Rugged
Winding Quantity: 1
Purpose For Which Designed: General
Coil Quantity: 1
Duty Type: Continuous
Mounting Facility Type And Quantity: 2 Unthreaded Hole Single Mounting Facility
Storage Type: General Purpose Warehouse
Cubic Measure: 29.800 Cubic Inches
Mounting Facility Pattern: In-Line Single Mounting Facility
Nonpile-Up Main Contact Arrangement: 1 Pole, Single Throw, Normally Open, Momentary Action
Time Delay: 0.01 Seconds Maximum Fixed Release Time
Time Delay: 0.025 Seconds Maximum Fixed Operate Time
Operating Voltage Rating And Type At Specified Temp: 28.0 Volts Dc 25 Deg Celsius Single Winding
Main Contact Load Current Rating At Maximum Rated Voltage: 200.0 Amperes Dc Resistive Load
Main Contact Maximum Voltage Rating In Volts: 28.0 Dc
Test Data Document: 81349-Mil-R-6106 Specification (Includes Engineering Type Bulletins, Brochures,Etc., That Reflect Specification Type Data In Specification Format; Excludes Commercial Catalogs, Industry Directories, And Similar Trade Publications, Reflecting General Typedata On Certain Environmental And Performance Requirements And Test Conditions That Are Shown As "Typical", "Average", "Nominal", Etc.).
Terminal Type And Quantity: 4 Threaded Stud All Functions
Specification/Standard Data: 96906-MS24171 Government Standard